Clearfox Windows · Planning guides
Window solar heat-gain coefficient explained
By JR Digital Services editorial team · Published 6 November 2026
Swipe tables sideways to see every column.
Illustrative stock photograph, not a local project or provider’s work. Photo: Jan van der Wolf. Pexels License.
What window SHGC actually measures
SHGC stands for solar heat gain coefficient. It is expressed as a number between 0 and 1, and it measures how readily heat from direct sunlight flows through a whole window — glass and frame together. The lower the number, the less solar heat that window transmits into your home. The coefficient includes directly transmitted solar energy and the inward-flowing portion of absorbed solar energy; it is not direct light transmission alone.
The figure is always calculated at a 0° angle of incidence — that is, with the sun perpendicular to the glass. This is the maximum possible solar heat gain condition. In practice, the angle of the sun relative to your window changes with orientation, season and time of day, so the actual solar gain through any installed window will vary from the declared number. That does not make the declared SHGC useless — it is a consistent, standardised basis for comparing products — but it does mean you cannot read it as a fixed prediction of how warm a particular room will get.
How SHGC differs from U-value
These two figures describe different heat pathways, and they are easy to confuse.
- U-value (Uw) measures how readily a window conducts heat by conduction — the non-solar pathway. A lower U-value means better resistance to heat flowing through the window due to temperature difference alone (for example, cold outside, warm inside on a winter night). The lower the number, the better the insulation.
- SHGC (SHGCw) measures the solar pathway — how much of the sun’s radiant energy passes through. Lower means less solar heat enters.
Both figures describe whole-window performance (glass and frame together), not the glass alone. A very efficient double-glazed unit with a thermally broken frame might have a low U-value but a relatively high SHGC if the glass type allows plenty of sunlight through. Neither number alone tells the full story — you need both, and you need to understand which matters most for a given orientation.
For Adelaide, which sits in a temperate mixed climate, both figures are relevant. North-facing glazing that benefits from winter sun typically warrants attention to SHGC alongside U-value. West-facing glazing exposed to late-afternoon summer sun makes a low SHGC particularly important. Your window supplier or energy assessor is the right person to advise on what targets suit your specific home design.
Finding SHGC on the certified product report
When a supplier quotes you on windows, ask for the WERS (Window Energy Rating Scheme) certified product report or data sheet for the specific product being proposed. WERS provides U-value, SHGC, air infiltration and visible light transmittance figures for rated products.
Key things to check on that document:
- Is it AFRC-compliant? Under the National Construction Code, window performance data must be determined in accordance with the guidelines of the Australian Fenestration Rating Council (AFRC). The YourHome guidance states you should look for evidence that ratings are AFRC approved, and if unsure, question the supplier or refer to the Australian Glass and Window Association.
- Is the figure labelled SHGCw? The w suffix indicates a whole-window figure (glass and frame combined). Glass-only figures are different and are not what NCC compliance requires.
- Does the report match the quoted product exactly? The AGWA window selection guide notes that to verify WERS custom-rated products, the glass description and frame description (including frame material type and operator type) on the WERS Certified Products Directory must match the quote description. A data sheet for a casement window in thermally broken aluminium with a particular glass make-up does not apply to a sliding window in standard aluminium with different glazing.
Matching the report to what is actually being quoted
This is where misreads most commonly occur. A supplier may show a data sheet for one configuration of a product range while quoting a different configuration. The SHGC can vary significantly depending on:
- Frame material and thermal performance — aluminium conducts heat readily; thermally broken aluminium, uPVC and timber frames behave differently, and frame choice changes the whole-window figure.
- Glass type — high-transmission low-e glass, low-transmission low-e, toned or clear glass each produce different SHGC values in the same frame.
- Window operation style — a fixed lite, an awning and a sliding window in the same frame system can have different air infiltration and potentially different rated SHGC values depending on how the product was tested.
A hypothetical scenario (illustrative only, not a customer story): imagine a homeowner is shown a product brochure listing SHGC 0.28 for a double-glazed casement in a thermally broken frame, but the quote they receive is for a standard aluminium sliding window with a different glass unit. The 0.28 figure does not apply. Asking the supplier to identify specifically which row of the WERS directory applies to the quoted product — and to show you that listing — is a reasonable and practical step before signing.
Questions orientation raises that SHGC alone cannot answer
The actual solar heat entering a room depends on the incident sunlight, glazing area, orientation and shading as well as the product coefficient. Ask the energy assessor how the quoted whole-window SHGC is used for each opening in the home’s assessment. Do not interpret an orientation example as the product exceeding its declared coefficient or as a prediction of room temperature.
This means choosing a single SHGC for all windows in a home without considering orientation is an oversimplification. For temperate climates including Adelaide, the YourHome guide notes that north-facing glazing generally suits a higher SHGC (to capture winter sun), while east- and west-facing glazing benefits from either effective shading or a lower SHGC. South-facing glazing is less critical for solar gain in these latitudes.
Shading — overhangs, awnings, external screens — interacts with SHGC and is part of the whole-of-home picture. A window with a moderate SHGC combined with well-designed shading may perform better in practice than a low-SHGC window with no shading, depending on orientation. These trade-offs are better assessed through tools like NatHERS or by an energy assessor than by reading a single product figure in isolation.
Keeping a product SHGC figure separate from a performance or savings prediction
A certified SHGC figure describes a physical property of a specific window product under standardised conditions. It is not a prediction of your energy bills, your room temperatures or the size of air conditioner you will need.
The YourHome guide explicitly notes that glazing needs to work together with orientation, thermal mass, insulation and weather sealing to deliver good thermal performance, and that the Australian Glass and Window Association tool can be used to explore potential impacts of glazing choices — not that any single figure guarantees an outcome.
If an energy report has been produced for your home or project, the AGWA selection guide explains that the report will specify required U-value and SHGC values, and that the actual window installed must meet those specifications — the U-value equal to or less than specified, and the SHGC within 10% of the specified value. That compliance check is a separate step from reading a brochure SHGC figure. If you have an energy report and are unsure whether the quoted window meets its requirements, that is a question for the supplier and your energy assessor, not something a product data sheet resolves on its own.
For further information on how WERS ratings are structured and how they relate to South Australian building requirements, see our related guide on WERS ratings explained. Questions about how glazing spacers and seals affect product integrity are covered in our guide on glazing spacer and seal questions.
Further reading
- YourHome — Glazing: https://www.yourhome.gov.au/passive-design/glazing
- AGWA Guide to Window and Door Selection: https://www.agwa.com.au/common/Uploaded%20files/AGWA/Technical/AGWA%20Guides/AGWA%20Guide%20Series-Selection.pdf
- WERS product search: https://werslink.com.au/wers/search.html