Clearfox Windows · Planning guides
Glazing spacer and seal questions
By JR Digital Services editorial team · Published 6 November 2026
Swipe tables sideways to see every column.
Illustrative licensed stock photograph of a room with windows. The named opening mechanism, flashing detail, spacer or seal is not demonstrated. Photo: Curtis Adams. Pexels License.
What does a double glazing spacer actually do—and why does it matter before you sign?
When you are comparing double glazing proposals in Adelaide, the glass panes tend to get all the attention. The spacer bar and seals are equally worth understanding, because they determine the structural integrity of the insulated glass unit (IGU) itself. Before accepting a quote, it is reasonable to ask what the proposed unit contains, how it is specified on paper, and what the warranty actually covers. This article explains what to look for in a specification, which questions are worth raising with your installer, and how to record what you have been promised.
What an IGU actually contains
An insulated glass unit consists of two or more glass panes manufactured as a single assembly, with a trapped air (or gas) gap held apart by a spacer bar. According to the Australian Glass Group product description for Insulglass Classic®, the spacer bar is desiccant-filled and the unit uses primary and secondary seals, described collectively by the manufacturer as serving structure and performance. The desiccant absorbs any residual moisture inside the cavity, which is why a properly sealed unit should not show fogging between the panes under normal conditions.
Your Home (the Australian Government’s sustainable housing guide) notes that the spacer also contains a desiccant to absorb moisture, and that inadequate desiccant may cause moisture to condense on the inner glass surfaces in cold conditions, reducing thermal performance. That is not the same as surface condensation on the outside of the frame, which is a separate issue relating to relative humidity and frame temperature.
The cavity fill also matters. Some units are filled with argon gas rather than dry air; the Australian Glass Group specifies argon gas as standard in Insulglass Classic® units (noting possible exclusions for some specialised sizes). Whether the unit proposed for your home includes an inert gas fill—and which gas—is a reasonable question to put in writing before ordering.
Reading a glazing specification correctly
A properly written IGU specification describes each layer in sequence: external pane thickness and type, spacer thickness, and internal pane thickness and type. The Australian Glass Group’s specification notation, for example, runs in the format 6/12/6—meaning 6 mm external glass, 12 mm spacer (and cavity), 6 mm internal glass. The spacer thickness governs the cavity width, which in turn affects the U-value.
If a quote describes your windows only as “double glazed” without listing the makeup, ask the supplier to provide the full specification. This matters because the declared U-value and Solar Heat Gain Coefficient (SHGC) on a Window Energy Rating Scheme (WERS) certificate are whole-window values derived from a specific glass and frame combination. Substituting a thinner spacer or a different glass type can alter the rated performance. The Australian Glass and Window Association (AGWA) advises keeping your WERS certificate so that if glass ever needs to be replaced, you can confirm the exact makeup of the original unit.
Questions worth asking your installer about spacers and seals
The following are genuinely useful things to clarify before work begins. They are framed as questions rather than checklists because the right answer depends on your specific unit and supplier.
- What is the exact IGU makeup for each window on this project? Ask for it written on the quote or schedule: external glass type and thickness, spacer type and thickness, cavity fill, internal glass type and thickness.
- What Australian Standard does the IGU comply with? IGUs should comply with AS 4666; ask the supplier to confirm this in writing.
- Is the spacer bar warm-edge or conventional aluminium? Aluminium spacers can act as a thermal bridge at the edge of the unit, contributing to condensation on the inner face of the glass near the frame. Warm-edge spacers use less conductive materials. The significance of this difference in your climate zone is a question for your installer.
- What sealing system is used, and what does the product warranty cover? A primary and secondary seal is a common IGU construction (as described for Insulglass Classic®), but what happens if seal failure occurs—and over what period—is determined by the manufacturer’s specific warranty documentation, not by any general industry promise. Ask for the written warranty before you sign.
- Is the desiccant fill adequate for the cavity size? This is particularly worth asking if you are ordering a large-span unit or if the spacer specification has been changed from the original quote.
A hypothetical illustration of information gaps
The following is a hypothetical scenario to illustrate why written specification matters—it is not a customer story or outcome prediction.
Imagine a householder in an inner-Adelaide suburb receives two quotes for double glazing. Both describe “24 mm double glazed units.” On closer inspection, Quote A specifies 6/12/6 with a 12 mm argon-filled cavity and a warm-edge spacer, while Quote B shows 4/16/4 with a 16 mm air cavity and an aluminium spacer bar. The total unit thickness is similar; the declared U-values, condensation behaviour at the frame edge, and applicable performance data differ. Without written specification, the householder cannot compare the two proposals on an equivalent basis or verify what was installed after the fact.
This is exactly the scenario the AGWA recommendation to retain WERS certificates is designed to address: having a written record means future glass replacement can match the rated combination.
Condensation, the spacer and the desiccant—what is and is not a defect
Surface condensation on the inner face of your window glass in winter is usually a function of room humidity and frame temperature—it does not automatically mean the IGU seal has failed. Your Home notes that keeping internal surfaces above dew point requires appropriate insulation, double or triple glazing, and thermally improved window frames together.
Fogging or persistent misting between the two panes of a sealed unit is a different matter and warrants professional assessment—it is not something a householder can reliably diagnose from the outside. If you observe this condition, document it with photographs, note when it first appeared and under what conditions, and report it in writing to your installer or the IGU manufacturer, referencing the product specification and warranty you were given at installation. A qualified assessor can advise on what, if anything, the observation indicates about the unit’s condition.
Clarifying what the warranty actually says
Warranty terms on IGUs vary between manufacturers and installers. Before work begins, ask for:
- The manufacturer’s written warranty for the IGU itself (the sealed unit)
- The installer’s workmanship warranty for the frame and installation
- What voids each warranty—for example, whether cleaning products applied to the frame or glass surface affect coverage
- Whether the warranty is transferable if the property is sold
Do not rely on verbal assurances. In South Australia, domestic building work above certain thresholds requires a written contract, and builder responsibilities include meeting plan specifications and legal requirements. That statutory context does not substitute for a clear product warranty document from the IGU manufacturer.
Recording the specification at handover
When installation is complete, keep a copy of:
- The written specification or schedule listing each window’s IGU makeup
- Any WERS certificate or compliance certificate supplied by the manufacturer
- The manufacturer’s IGU warranty document
- The installer’s workmanship warranty or contract
If you later need to replace a broken pane, match a unit for an extension, or sell the property, this paperwork provides product-identification information to discuss with a professional, who may also be able to identify the unit by other means. The AGWA guidance on window selection specifically recommends retaining the WERS certificate for exactly this purpose.
For broader context on how the whole-window performance figures relate to Adelaide’s climate, see our guide to window solar heat-gain coefficient explained.
Further reading
- Australian Glass Group, Insulglass Classic® product page: https://agg.com.au/product/insulglass-classic/
- Australian Government Your Home, Glazing: https://www.yourhome.gov.au/passive-design/glazing
- Australian Government Your Home, Condensation: https://www.yourhome.gov.au/passive-design/condensation
- AGWA / WERS, Energy Efficient Windows: https://www.agwa.com.au/WERS/WERS/Energy-Efficient-Windows.aspx
- SA Government, Builder responsibilities: https://www.sa.gov.au/topics/business-and-trade/building-industry/planning-professionals/builder-responsibilities
If you would like to explore whether a referral to a window installer in Adelaide is available for your project, you are welcome to use the enquiry form on this site.